Utredningen som riktar sig till hälso- och sjukvårdspersonal, har utformats utefter tillgänglig litteratur och resurser vid tidpunkten för utredning. Innehållet i utredningen uppdateras inte. Hälso- och sjukvårdspersonal är ansvarig för hur de använder informationen vid rådgivning eller behandling av patienter.


What is known about passage of lidocaine and bupivacaine into breast milk?



Fråga: What is known about passage of lidocaine and bupivacaine into breast milk?

Sammanfattning: Systematic documentation of milk passage of lidocaine and bupivacaine is missing. Based on case reports described in the literature small amounts are excreted into milk, but total amounts to the infants appear to be negligible.

Svar: The disposition kinetics and placental transfer of the amide type local anesthetics (lidocaine and bupivacaine) have been well characterized. Very little is known, however, about their excretion to milk, and even less information is available concerning the ensuing concentrations or effects in breast milk fed infants. For local anesthetics in general, it is characteristic that relatively low systemic levels are seen in relation to clinically applicable doses. This is partly due to usual routes of administration (aiming at local instead of systemic effects). This can also be due to the pharmacokinetic characteristics of these drugs.

The pH of milk favors passive diffusion of basic drugs like amide type local anesthetics to milk due to ion trapping. Increases in the unbound fractions of lidocaine and bupivacaine have been observed during pregnancy (1). Thus, this represents another factor which could increase the milk to plasma (M/P) ratio and excretion of these agents in milk - at least in the early post-partum period. In addition, plasma protein binding of lidocaine and bupivacaine in cord or infant serum are lower than in adult serum (2). Our current knowledge about lidocaine and bupivacaine milk concentrations is based on a few case reports described in the literature. A Medline search covering years 1966-1994 was performed for this review.

There is a case report describing lidocaine excretion in milk during intravenous treatment of ventricular arrhythmias (3). Concentration of lidocaine in milk was 40 per cent of mother´s serum concentration (ie M/P ratio of 0.4). It was calculated that if a maximum allowed serum concentration (5 ug/ml) is maintained, the total daily dose for the infant would be 1.4 mg (0.35 mg/kg) assuming a daily milk consumption of 700 ml. The weight-adjusted relative dose would be less than one per cent. Thus, the dose to the infant appears to be very small even in this "worst case" scenario. A newborn child or even a fetus are capable of metabolizing lidocaine. An elimination half-life of approximately 3 h has been reported in infants (4,5), ie almost double to that of adults. This is most probably due to increased volume of distribution. Total plasma clearance normalized to body weight showed no significant difference between neonates and adults (6).

The plasma concentrations of lidocaine in the nursing mother remain, however, much lower than 5 ug/ml in most clinical situations (ie after local or regional anesthesia). In a recent case report, a significantly higher M/P ratio (1.1 for lidocaine, 1.8 for monoethylglycinexylidine) was found after a single 20 mg lidocaine injection for dental extraction (7). The calculated daily infant doses for the parent drug and the metabolite were both less than 0.01 mg/kg. In studies using relatively rough estimates of the well-being of newborn infants (eg Apgar score, weight gain), no harmful effects associated with the use of local anesthetics have been observed (8). The American Academy of Pediatrics considers lidocaine as a safe drug for nursing mothers (9).

In a case report, milk bupivacaine concentrations were below the detection limit (0.02 ug/ml) after cesarean section under epidural anesthesia (10). This finding fits to the high plasma protein binding and ionisation of the drug. There is also an interesting case report where bupivacaine was given as a continuous infusion into the interpleural space for postoperative pain control to a nursing mother (11). After a bolus dose of 50 mg a maintenance infusion was given for 5 days at a rate of 25 mg/h. Concentration in the milk was 0.4 ug/ml after 6 hours and declined thereafter to 0.1 ug/ml. 60 h after starting the treatment no detectable plasma levels were observed in the infant. The total daily amount to the newborn would thus be only 0.06 mg/kg even using the higher concentration in the calculation. The respective weight-adjusted relative dose would thus be only 0.6 per cent.

The blood levels of bupivacaine after lumbar epidural anesthesia have been measured in 6 mothers and their infants during and after the delivery (12). Maternal blood levels were over three times higher than umbilical vein levels at delivery. The disappearance of bupivacaine from the blood was, however, significantly lower in newborns than in adults. An average plasma half-life of 25 h was observed. These results strongly suggest that neonates are less able to metabolize this drug than adults.